Firepan Anti-Ligature BF60

Panelcraft Access Panels have developed the Firepan Anti-Ligature Range to provide an effective safe solution for vulnerable applications.



Anti-ligature Disclaimer

The anti-ligature design elements of this access panel are not intended to replace the need for necessary supervision of those who may be at risk, or for other mandatory protective measures to be utilised for the specific usage. We do not offer any products for sale as being "ligature-free" and will not be liable for claims associated with ligature attachment on its hatches/panels.



Further Information

  • ❑   1 Hour Fire Rated certified to BS 476 Part 22
  • ❑   UKAS Acoustic test to 36dB reduction
  • ❑   Suitable for Walls and Ceilings
  • ❑   Beaded Frame option


Stock Panel Sizes

 CODE  PANEL SIZE  STRUCTURAL OPENING  CLEAR OPENING ONCE INSTALLED DEPTH  WEIGHT 
 Fire Rated BF150  150 x 150mm  160 x 160mm  75 x 80mm  50mm  2.6kg
 Fire Rated BF200  200 x 200mm  210 x 210mm  120 x 140mm  50mm  4.3kg
 Fire Rated BF300  300 x 300mm  310 x 310mm  220 x 264mm  50mm  5.6kg
 Fire Rated BF350  350 x 350mm  360 x 360mm  270 x 314mm  50mm  7.7kg
 Fire Rated BF450  450 x 450mm  460 x 460mm  370 x 412mm  50mm  10.6kg
 Fire Rated BF550  550 x 550mm  560 x 560mm  470 x 514mm  50mm  12.0kg
 Fire Rated BF600*-300  600 x 300mm  610 x 310mm  565 x 235mm  50mm  6.7kg
 Fire Rated BF600  600 x 600mm  610 x 610mm  520 x 564mm  50mm  16.9kg

* Hinged on the longer side.




More Information

❑   The panel is made to fit into the opening (the outer frame is an extra 25mm on each side)25mm picture frame (projects beyond the face of the opening), 50mm deep panel (depth into the opening)

❑   60 minute fire rating suitable for a wide range of applications including Gas Flue inspection hatches

❑   Colour white polyester powder coating, RAL9010 with 20% gloss

❑   Tested to B.S.476: Part 22:1987 and Part J Compliant

❑   36dB sound reduction rating

❑   Dual purpose for either walls or ceilings

❑  Zintec steel for a corrosion resistant finish

❑   Product made to order, please note this item is non-returnable



Insulated Meter Box Technical Drawing


Fitting instructions for Firepan Range of Panels into wall.

Structural Opening to be formed Level, Plumb and Square
The structural Opening should be lined with 12.5mm Fireline board.
The aperture after lining is fitted should be 10mm greater than the panel.
For example, a 2300 x 950 panel needs a structural opening of 2310 x 960 after being lined with the Fireline board


Insert the Frame into the opening.
Fix Frame using a 75mm steel screws using the pre punched holes in the frame on all four sides (do not fully tighten).
Ensure equal gap around all sides of the Frame Then fully screw fix ensuring the frame remains square and plumb. Ensure all fixings are solid but do not over tighten as this could distort the frame.


Apply a 5mm wide bead of Intumescent Sealant (2 Hours Minimum Rated)
to the back edge of the frame /aperture lining connection.


On larger doors it is advised the door is removed from the frame by unbolting the door and lifting from the hinge studs. Re hang the door once the frame is fixed and secure. Ensuring gap is equal top and bottom before re bolting the door into the frame.


External Wall Insulation Electric Meter Box




LENGTH CONVERTER

Type a value in the Inches field to convert the value to mm:

mm

NEED FURTHER ASSISTANCE?

SHARE US

Instagram
Pinterest
MADE IN THE UK




Further Related products



Firepan PF60




MORE INFORMATION
Firepan BF60




MORE INFORMATION
Duplex Riser Door PF/BF90




MORE INFORMATION
Duplex Riser Door PF/BF120




MORE INFORMATION
Firepan Anti-Ligature PF60




MORE INFORMATION
Firepan Anti-Ligature BF60




MORE INFORMATION
Firepan Budget PF/BF120




MORE INFORMATION
Firepan Budget PF/BF120




MORE INFORMATION
Duplex Double Riser Door PF/BF90




MORE INFORMATION